The Model 107 K2 adiabatic demagnetization refrigerator (ADR) is specially designed for experiments needing high cooling power. By employing a 3He cooler that offers a high power 300 mK intercept, more of the ADR cooling power can go towards your experiment. This mid-sized research cryostat features an experimental volume of 34 cm in diameter and 20 cm tall. If your cooling needs are greater than a standard ADR, but still less than a dilution refrigerator (DR), the Model 107 K2 may be just the ticket. Call us to discuss how we can optimize the Model 107 K2 to fit your needs.

Medium, cylindrical, pulse-tube, 3He backed, single stage ADR cryostat


Features:

Specifications:

107 Shasta 3He-Backed ADR Cryostat, Cryocooler

The Model 107 K2 3He backed, single stage ADR cryostat, with vacuum jacket and radiation shields removed.

3 K space of the Model 107 K2 Cryostat

3 K space of the Model 107 K2 Cryostat.

Model 107 cryostat seen from the bottom

Model 107, K2, cryostat seen from the bottom.

Compare ADR Cryostat Models

102 Cryostat 103 Cryostat 104 Cryostat 106 Cryostat 107 Cryostat 124 Cryostat
Pulse Tube Two Stage ADR Cryostat
Pulse Tube Two Stage ADR Cryostat
Pulse Tube Two Stage ADR Cryostat
Pulse Tube Two Stage ADR Cryostat
Pulse Tube, He-3 Backed, Single Stage ADR Cryostat
Tabletop GM Cooler Two Stage ADR Cryostat
Vacuum Jacket Size
33 cm X 22 cm X
66 cm Tall
Vacuum Jacket Size
Ø 35 cm X 69 cm Tall
Vacuum Jacket Size
Ø 55 cm X 110 cm Tall
Vacuum Jacket Size
Ø 44 cm X 65 cm Tall
Vacuum Jacket Size
Ø 44 cm X 65 cm Tall
Vacuum Jacket Size
Ø 44 cm X 65 cm Tall
Experimental Volume
24 cm X 15 cm X
14 cm Tall
Experimental Volume
Ø 26 cm X 25 cm Tall
Experimental Volume
Ø 44 cm X 60 cm Tall
Experimental Volume
Ø 34 cm X 21 cm Tall
Experimental Volume
Ø 34 cm X 21 cm Tall
Experimental Volume
Ø 34 cm X 20 cm Tall
1st Stage Cooling Power
25 W @ 55 K
1st Stage Cooling Power
25 W @ 55 K
1st Stage Cooling Power
35 W @ 45 K
40 W @ 45 K
1st Stage Cooling Power
25 W @ 55 K
35 W @ 45 K
40 W @ 45 K
1st Stage Cooling Power
25 W @ 55 K
35 W @ 45 K
40 W @ 45 K
1st Stage Cooling Power
40 W @ 55 K
2nd Stage Cooling Power
0.7 W @ 4.2 K
2nd Stage Cooling Power
0.7 W @ 4.2 K
2nd Stage Cooling Power
1 W @ 4.2 K
1.5 W @ 4.2 K
2nd Stage Cooling Power
0.7 W @ 4.2 K
1 W @ 4.2 K
1.5 W @ 4.2 K
2nd Stage Cooling Power
0.7 W @ 4.2 K
1 W @ 4.2 K
1.5 W @ 4.2 K
2nd Stage Cooling Power
1.5 W @ 4.2 K
GGG Cooling Capacity
1.2 J @ 1 K
GGG Cooling Capacity
1.2 J @ 1 K
GGG Cooling Capacity
1.2 J @ 1 K
GGG Cooling Capacity
1.2 J @ 1 K
He-3 Cooling Capacity
15-20 J @ 300 mK
GGG Cooling Capacity
1.2 J @ 1 K
ADR Base Temperature
< 50 mK
ADR Base Temperature
< 50 mK
ADR Base Temperature
< 50 mK
ADR Base Temperature
< 50 mK
ADR Base Temperature
< 30 mK
ADR Base Temperature
< 50 mK
FAA Cooling Capacity
120 mJ @ 100 mK
FAA Cooling Capacity
120 mJ @ 100 mK
FAA Cooling Capacity
120 mJ @ 100 mK
FAA Cooling Capacity
120 mJ @ 100 mK
FAA Cooling Capacity
200 mJ @ 100 mK
FAA Cooling Capacity
120 mJ @ 100 mK
Click HERE to learn more from an HPD sales engineer...
High Precision Devices, Inc.
1668 Valtec Lane, Suite C Boulder, CO 80301 USA
Phone: +1-303-447-2558 Email: info@hpd-online.com